Site services · Sourced through our provider network

Office trailer rental.

A lockable room on site for drawings, meetings and a laptop that isn't balanced on a tailgate. We source container offices, office and storage combos and wheeled office trailers from local providers, and we keep the dates, the delivery and the bill in one place.

Container officeSteps and railPower
  • Panel125 amp inside, a disconnect outside, on the units we looked at
  • AirA through-wall heat and cool unit
  • DoorSteps, and a ramp if the public uses it

What you can rent

Three kinds of site office.

They all give you four walls, a door that locks, light and air. The difference is how they get to your site, what sits beside the desk and how high the floor ends up.

TypeWhat it isGood whenPlan for
Container officeA steel shipping container that's been framed, insulated and wired, with windows, a personnel door and a wall unit for heat and cooling. Usually 20 or 40 feet long and 8 feet wide.You like steel walls, a short step up to the door and a footprint that fits a tight lot.A level, firm pad and room for the truck that sets it.
Office and storage comboOne container with a wall inside: a finished office at one end and a lockable storage room behind the cargo doors at the other.The same crew needs a desk and a place to lock up tools or materials.Which end faces the road, so the cargo doors open where trucks can reach them.
Wheeled office trailerAn office built on a trailer frame with axles and a hitch. It's towed in, then leveled on site.You need more floor space or more rooms than one container gives.A tow path, a taller step up to the door, and stairs or a ramp to match.

What we've placed

34 site offices in 18 states over two years.

Container offices are most of what we book. They're 21 of the 34, set in 12 states by 18 different local providers, and our first one went out in July 2025. The rest are office and storage combos plus a few wheeled office trailers.

Site offices delivered
34
States
18
Median stay, all office types
77 days
Median stay, container offices
70 days

Updated October 29, 2026. Counts cover office units delivered October 26, 2024 through October 26, 2026, canceled orders excluded. Stay length runs from delivery to pickup on the 26 units that had gone back, 17 of them container offices. The middle half of those stays ran 55 to 118 days.

What that means for you: most site offices stay a season, not a week. About two and a half months is typical, and a quarter of them stayed 118 days or longer. If your job runs longer, say so up front, because it changes which provider and which unit makes sense.

What comes inside

Two 20 foot container offices, spec by spec.

Two manufacturers publish full specs for a 20 foot office built from a new container. They're a fair picture of what a provider will deliver. Your provider's unit may differ, so the quote is what counts.1

SpecBuilder ABuilder B
Outside8 ft wide, 19 ft 10.5 in long, 8 ft 6 in high20 ft container, standard height
Inside7 ft wide, 18 ft 6 in long, 7 ft 4 in highInsulated wall panels, 2 3/4 in thick
Electrical125 amp panel with a 60 amp exterior disconnect, six duplex 110 volt outlets125 amp breaker box, an exterior junction box, five plug outlets and one switched outlet
Heat and coolingThrough-wall unit, 15,000 BTU cooling and 3.5 kW heat8,000 BTU heat pump on 110 volts, with a 12,000 BTU, 220 volt upgrade
WindowsThree, 3 ft by 3 ftThree 36 in sliders with security bars
DoorOne 3 ft personnel door with a light beside itOne steel door, 3 ft by 6 ft 8 in, with a 3 hour fire rating
LightsTwo 4 ft LED fixturesTwo 4 ft fluorescent fixtures

The same builder that makes the 20 foot combo also lists a 40 foot combo with a 16 foot office and 24 feet of storage.1 If you mostly need storage with a desk at one end, that's the layout to ask about. For storage alone, see storage container rental.

That 60 amp disconnect on the outside wall is where site power lands. A licensed electrician connects it, either to a temporary service or to a generator through a transfer switch. Our temporary power page covers both, with a calculator that adds up the watts.

Ask about the air unit. A 15,000 BTU through-wall unit and an 8,000 BTU one on 110 volts are very different in July. If your office will hold several people and computers, ask which one you're getting and what power it needs.

Office steps and ramp calculator

How far up is the door, and what does that call for?

Measure from the ground to the top of the door threshold once the unit is set and leveled. This applies OSHA's construction stair rules and the 2010 ADA Standards ramp rules to that one number.

Your office door

The 24 inch default is only a starting point. A container office on blocks sits lower than a wheeled trailer on its frame, so measure yours.

34 ftstraight ramp with landings1 run totaling 24 ft at 1:12, plus 2 landings 5 ft long

OSHA stairway or ladder
Needed, unless there's a ramp
Stair handrail and stairrail
Needed if the steps have 4 or more risers
Ramp handrails
Both sides
Ramp runs
1

Ramp numbers are the minimum at the steepest slope the ADA Standards allow, laid out in a straight line. A ramp that turns needs a landing at least 60 by 60 inches at each turn.

The rules behind the numbers

Steps for your crew. A ramp when the office has to be accessible.

On a construction site, OSHA wants a stairway or ladder at any access point with a break in elevation of 19 inches or more, unless a ramp, runway, sloped embankment or personnel hoist is there instead.2 Once the stair has four or more risers or rises more than 30 inches, whichever comes first, it needs at least one handrail and a stairrail on each open side.3

Accessibility is a separate question. The 2010 ADA Standards say construction trailers and other structures tied to the actual process of construction don't have to comply or sit on an accessible route.4 A sales office, a leasing office or a field office the public walks into is different. If that's yours, check with the building department before the unit arrives, because the ramp is often longer than people expect.

  • SlopeNo steeper than 1:12, so every inch of rise takes at least 12 inches of ramp.
  • Rise per run30 inches at most, then a landing before the next run.
  • LandingsAt the top and bottom of every run, at least 60 inches long, and 60 by 60 inches where the ramp turns.
  • Width and rails36 inches clear, with handrails on both sides once a run rises more than 6 inches, their tops 34 to 38 inches up.
  • The doorA clear opening of at least 32 inches.

ADA Standards sections 405.2, 405.5, 405.6, 405.7, 405.8, 505.2, 505.4 and 404.2.3.4

Before it arrives

Five things to sort out before delivery day.

Have these answers ready when you ask for a quote and the order moves faster.

  • A level, firm spotLong and wide enough for the unit, plus room on the door side for the steps or ramp you worked out above.
  • A clear path inNo low wires, soft ground or tight turns between the street and the spot. Tell us if the only way in is over a curb or through a gate.
  • A power planWho brings power to the exterior disconnect and when. A utility temporary service isn't instant. One large utility says it needs at least 10 business days when it has to build line, and that's before inspection.5
  • Keys and furnitureAsk how many keys come with it and whether desks, chairs or a plan table are included or extra.
  • The building departmentAsk whether the office needs its own permit or tie-downs where you are. Ask before it's set, not after.

Get an office quote.

Send the address, the dates, how many people will work in it, and whether you need storage too. Tell us how power will get there. We'll check which local providers have a unit for those dates.

Questions

Questions about site offices.

What's the difference between a container office and an office trailer?

A container office is a converted steel shipping container set on the ground. An office trailer is built on a frame with axles and a hitch and gets towed in. A trailer can give you more floor space and more rooms. A container sits lower and has steel walls.

How long do people rent a site office?

In our network the median stay is 77 days, from delivery to pickup, and the middle half of stays ran 55 to 118 days. That's 26 units delivered between October 2024 and October 2026 that had already gone back.

Does a construction site office have to be ADA accessible?

Not under the 2010 ADA Standards when it's a construction trailer used for the work itself; section 203.2 exempts it. An office the public uses, like a sales or leasing office, is another matter, so check with the building department.

Do I need stairs for an office trailer?

OSHA calls for a stairway or ladder when the step up is 19 inches or more and there's no ramp. Stairs with four or more risers, or that rise more than 30 inches, need a handrail and a stairrail on each open side.

What power does a container office need?

The units we looked at have a 125 amp panel inside, and one has a 60 amp disconnect outside. A licensed electrician connects site power to it, or a generator does. Ask the provider for the exact connection on the unit you're getting.

Read next

Sources

  1. Manufacturer spec pages, checked October 29, 2026: Falcon Structures 20 ft Shipping Container Office (exterior 8 ft by 19 ft 10.5 in by 8 ft 6 in; interior 7 ft by 18 ft 6 in by 7 ft 4 in; 125A capacity panel with 60A exterior disconnect; six duplex 110V outlets; two 4 ft LED fixtures; PTAC with 15k BTU cooling and 3.5 kW heating; three 3 ft by 3 ft windows; one 3 ft personnel door with exterior light) falconstructures.com; ModalART 20 ft Office Container and 40 ft Office Combo, new container builds (three 36 in by 36 in sliders with security bars; 3068 door with 3 hour fire rating; 2 3/4 in R-13 panels; 8,000 BTU heat pump at 110 volts, upgradable to 12,000 BTU at 220 volts; five plug outlets, one switch outlet, 125 amp breaker box, exterior junction box; two 4 ft fluorescent fixtures; 40 ft combo with 16 ft office and 24 ft storage) modalart.com.
  2. 29 CFR 1926.1051(a), General requirements for stairways and ladders: a stairway or ladder at all personnel points of access where there is a break in elevation of 19 inches or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. Checked October 29, 2026. ecfr.gov
  3. 29 CFR 1926.1052(c)(1), Stairways: stairways having four or more risers or rising more than 30 inches, whichever is less, shall have at least one handrail and one stairrail system along each unprotected side or edge. Checked October 29, 2026. ecfr.gov
  4. US Access Board, 2010 ADA Standards for Accessible Design: 203.2 construction sites, including construction trailers, not required to comply or be on an accessible route; 404.2.3 door clear width 32 inches minimum; 405.2 running slope not steeper than 1:12; 405.5 ramp clear width 36 inches minimum; 405.6 rise 30 inches maximum per run; 405.7 landings at the top and bottom of each run, 60 inches long minimum, 60 by 60 inches at a change in direction; 405.8 handrails where a run rises more than 6 inches; 505.2 handrails on both sides of ramps; 505.4 handrail height 34 to 38 inches. Checked October 29, 2026. access-board.gov
  5. Duke Energy, Requirements for Electric Service and Meter Installations, April 2026: for temporary construction service, the company holds the application for inspection, line construction when needed requires a minimum of 10 business days, and the authority having jurisdiction inspects the temporary meter base and notifies the company before the meter is installed. duke-energy.com
  6. Detritus provider network order records: office units delivered October 26, 2024 through October 26, 2026, canceled orders excluded; stay length from delivery to recorded pickup. Pulled October 29, 2026.